In the early 1940s, following the end of World War II, the United States faced a critical shortage of copper. To address this issue, the government introduced a "copper-on-aluminum" technology policy, mandating that industries adopt aluminum as an alternative conductor material. This shift prompted American wire and cable manufacturers to begin developing aluminum-core cables and wires. Over time, the U.S. became a pioneer in the production and application of aluminum conductors.
By the 1960s, significant advancements were made in aluminum core cable technology. Researchers discovered that aluminum conductors could be effectively used for communication lines, leading to further exploration of their potential. The UK even installed an aluminum-core telephone line in Antarctica to test its performance under extreme cold conditions. As composite metallurgy advanced, companies like Alcoa began developing electric-grade aluminum alloys with improved mechanical properties, such as increased strength, better ductility, and enhanced heat resistance. These new alloys were eventually categorized under the 8000 series, marking a major milestone in the industry.
During the early 1960s, aluminum conductors gained popularity in residential wiring in the U.S. and Canada, especially for smaller gauge wires (AWG 10 and 12). Due to its lower cost and wide availability, AA-1350 aluminum became widely used. However, by the late 1960s, many early installations began to fail, causing complaints from both the power sector and homeowners. This led to a re-evaluation of aluminum conductors.
In response to these issues, in 1970, various stakeholders—including wire and cable companies, electrical laboratories, and connector manufacturers—collaborated to improve aluminum conductor performance. New connectors were developed specifically for aluminum wiring, and after rigorous testing, the 8000 series aluminum alloys were selected for building wires. The AA-8030 alloy, in particular, was noted for its superior tensile strength, yield strength, and flexibility compared to the earlier AA-1350 grade.
By 1972, the U.S. national regulations mandated the use of 8000 series aluminum alloys for electrical wiring. Standards such as UL 486B were revised, and by the mid-1980s, the ASTM and NEC began incorporating 8000 series aluminum conductors into their specifications. In 1988, ASTM published B-800 and B-801 standards, officially recognizing the 8000 series for use in building and power cables. Since then, these alloys have been widely adopted globally.
While the U.S. led the way, China had already recognized the importance of "aluminum replacing copper" as a key policy in 1957. However, due to implementation challenges, the widespread adoption of aluminum cables lagged. After the reform and opening up, increased technical exchanges brought foreign aluminum products to China, raising awareness and prompting local industry upgrades.
Despite progress, one challenge remains: the development of installation hardware often lags behind the advancement of the cables themselves. For example, outdated overhead cable hardware has hindered the export of insulated cables. Countries like Finland, which export cables along with proper hardware, have set a successful example.
In recent years, global leaders such as the U.S., Canada, and Germany have successfully introduced aluminum alloy cables into China, sparking renewed interest. With the establishment of national standards and installation guidelines, China is now rapidly advancing in the field of aluminum alloy cables, proving that there is still much to learn and innovate in this area.