The allowable current carrying capacity of low-voltage power cables under long-term continuous load is a critical factor in electrical design and cable selection. This table provides the permissible current values for various types of PVC-insulated cables, including single-core and multi-core configurations, installed in air or buried in soil. The values are based on standard ambient temperatures of 40°C (for installation in air) and 25°C (for installation in soil).
â– 0.6/1kV PVC insulated power cable allows continuous current carrying capacity
|
model |
VV VLV VV22 VLV22 ZR-VV ZR-VLV ZR-VV22 ZR-VLV22 |
VV VLV VV22 VLV22 ZR-VV ZR-VLV ZR-VV22 ZR-VLV22 |
Number of cores |
Single core |
3-5 core |
Laying |
in the air |
In the soil |
in the air |
In the soil |
Single core cable arrangement |
â—‹ â—‹â—‹ |
â—‹â—‹â—‹ |
â—‹ â—‹â—‹ |
â—‹â—‹â—‹ |
Conductor material |
Cu |
Al |
Cu |
Al |
Cu |
Al |
Cu |
Al |
Cu |
Al |
Cu |
Al |
Nominal cross section |
1.5 |
19 |
... |
24 |
... |
27 |
... |
29 |
... |
15 |
... |
22 |
... |
2.5 |
25 |
19 |
31 |
24 |
36 |
27 |
38 |
30 |
19 |
15 |
29 |
23 |
4 |
33 |
26 |
41 |
32 |
47 |
35 |
49 |
39 |
26 |
20 |
38 |
30 |
6 |
41 |
34 |
52 |
42 |
58 |
46 |
61 |
50 |
32 |
26 |
47 |
39 |
10 |
57 |
44 |
72 |
55 |
78 |
58 |
83 |
64 |
46 |
35 |
65 |
50 |
16 |
76 |
59 |
95 |
73 |
100 |
76 |
105 |
83 |
60 |
47 |
84 |
65 |
25 |
98 |
76 |
120 |
96 |
130 |
95 |
135 |
105 |
77 |
60 |
110 |
84 |
35 |
115 |
90 |
150 |
115 |
155 |
115 |
160 |
125 |
95 |
74 |
130 |
100 |
50 |
145 |
110 |
180 |
140 |
185 |
140 |
195 |
150 |
115 |
90 |
155 |
120 |
70 |
180 |
140 |
230 |
175 |
225 |
170 |
240 |
185 |
145 |
115 |
195 |
150 |
95 |
225 |
175 |
280 |
215 |
270 |
205 |
285 |
220 |
185 |
140 |
230 |
185 |
120 |
260 |
200 |
325 |
250 |
310 |
235 |
325 |
250 |
210 |
165 |
260 |
205 |
150 |
300 |
230 |
375 |
290 |
350 |
265 |
365 |
285 |
245 |
190 |
300 |
230 |
185 |
345 |
270 |
430 |
335 |
395 |
300 |
415 |
320 |
280 |
215 |
335 |
260 |
240 |
410 |
320 |
510 |
395 |
455 |
350 |
480 |
375 |
335 |
260 |
390 |
300 |
300 |
475 |
370 |
585 |
455 |
515 |
395 |
545 |
425 |
375 |
295 |
435 |
340 |
400 |
555 |
440 |
690 |
540 |
585 |
455 |
625 |
490 |
... |
... |
... |
... |
500 |
640 |
510 |
800 |
630 |
660 |
520 |
710 |
560 |
... |
... |
... |
... |
630 |
730 |
595 |
920 |
740 |
740 |
590 |
810 |
645 |
... |
... |
... |
... |
Ambient temperature |
40 |
25 |
40 |
25 |
|

Concrete Water Reducer
Concrete Water Reducer,water reducers in concrete,concrete water reducer admixture,water reducing agent in concrete,plasticizer used in concrete
Shanghai Hongyun New Construction Materials Co., Ltd , https://www.hongyunpce.com